10 years

Alurail L rail

Highly smooth anti-fall rail

The Alurail L rail, in aluminium 6060 T6, is designed and engineered to guarantee maximum fluidity in flat, vertical, ceiling and to create spans of up to 6 m length.
The system guarantees low visual impact and reduced overall dimensions, and is equipped with accessories for easy installation and maintenance.

The traveller designed for Alurail L track has the following features:

  • 6060 T6 aluminium body
  • 6 bearings ball for perfect smoothness
  • brass protection against dirt and dust between the aluminium body of the shuttle and the bearings
  • anti-tamper cover to ensure maximum security
  • equipped with upper anchorage, with 180° working angle

 

Product
003911
Template
Alurail L 3m
Details

Alurail 3m long anodized aluminum fall arrest rail, can be fixed along the entire length of the profile. Ideal for ceiling-mounted lifelines where high smoothness is required.

Product
003910
Template
Alurail L 6m
Details

Alurail 6m long anodized aluminum fall arrest rail, can be fixed along the entire length of the profile. Ideal for ceiling-mounted lifelines where high smoothness is required.

Product
003848
Template
L Trly type ONE
Details

Trolley for Alurail L rail certified for the support of one person. Designed with high-strength anodised aluminium body and 316 stainless steel and brass rotating assembly. Anchor hook swivels 180° on perpendicular axis

Product
006806
Template
CG: Alur tubul
Details

CG: Alurail L tubular in accordance with customer's drawing

Product
003831
Template
Fixed terminal
Details
Fixed stainless steel 304 terminal for Alurail L with hammer head bolts for clamping on the rail
Product
003987
Template
Snap terminal
Details
Stainless steel 304 snap terminal for Alurail L, with hammer head bolts for fixing on the rail.
Product
003894
Template
Kit plug
Details
Kit composed by 2 alignement plug. Made in Stainless steel 304, they are used to preserve the alignation of the contiguous rails in case of thermal expansion.
Product
004737
Template
Cone. Alurail L
Details
Connection for Alurail L rail joint, external model. Max connection span 4m
Product
006522
Template
Alur L junction
Details

Junction for connecting Alurail L track, invisible model. Maximum connection span 1m

Product
005477
Template
Alurail L conne
Details
Alurail L junction designed to join both the track and the structural support tube.
Product
004239
Template
Expn bl Alur L
Details
Alurail L expansion plate with 1 Grower washer M10 and 1 self-locking nut M10
Product
004923
Template
Alurail L/S fixing stop
Details

304L polished and marked fixing plate with 35 mm bar for Alurail L and S with grower washer and self-locking nut

Product
005199
Template
GC:fix block Al
Details

Generic Code: Fixing plate 304L electro-polished and marked with variable length bar customizable to drawing for Alurail L and S with grower washer and self-locking nut

Product
002572
Template
Fixing Plate
Details
Pickled Fixing Plate for Alurail L and S without bolts
Product
004930
Template
Fix bl Alur L/S
Details
Fixing plate 304L Electropolished, marked with expansion system and bar length 35mm for Alurail L and S without screws
Product
004945
Template
Expn bl Alur L
Details
Fixing plate with expansion system for Alurail L, female hole type, for variable length. Bolts not included
Product
004215
Template
Brush kit
Details
Kit consisting of 2 rail cleaning brushes (1 front and 1 rear) with Alurail L shuttle mounting
Product
005128
Template
Alurail L plug
Details

Alurail L plug for closing the outer profile of the rail. Optimal for wasp and water/ice protection.

Product
005072
Template
Plug 60x60
Details
Plastic plug 60x60 for closing the reinforcement tubular of Alurail L rail
Product
004181
Template
SS S bracket
Details
Stainless steel S bracket for Alurail L
Product
004179
Template
L brackets
Details
Stainless steel L brackets for roof curbs
Product
004183
Template
SS C Bracket
Details
Stainless steel C bracket Length 80
Product
003984
Template
Omega bracket
Details
Omega Alurail L bracket
Product
004731
Template
Alurail L UPN SZ Joint Bracket
Details

Hot-dip galvanized external plate with stainless steel fixing plates and bolts

VIDEO

Alurail L track.

Smoothness and low visual impact

Binary FAQ.

According to UNI EN 795:2012 and Commission Implementing Decision (EU) 2015/2181 of 24 November 2015, only type B and E devices are required to bear the CE marking.

Maintenance, especially for safety systems, is mandatory (art. 15 DL 81/2008 and subsequent amendments). The Italian law regarding fall arrest systems requires an inspection according to the methods indicated by the manufacturer at least once a year or before their reuse if they have not been used for a long time (even several years).

The question is complex: what kind of testing are we talking about? The standard requires two tests: one regarding the anchors (the material used to attach them to the supporting structure: resin-threaded rods, structural screws, etc.), which must withstand the maximum forces generated by a falling operator, and a second to verify, in practice, that the installation has been carried out correctly. Unless otherwise specified by the manufacturer, for this last test, a force of 5 kN in the working direction must be applied to the anchor line post/plate for 15 seconds. In any case, both tests are mandatory; if the test is considered a test, the answer is YES.

The first action to take is to analyze the risks, and this cannot be done without taking into account the activities that will be performed.

All collective edge protection systems are included in the available solutions: parapets, safety nets, and combined systems (parapets and fall arrest nets). The choice of which to use depends on the characteristics of the roof and the client's needs.

Deformation-controlled devices dissipate part of the energy released during a worker's fall, thus reducing the load transmitted to the support structure. Although each device has its own breaking load, the elastoplastic deformation that the deformation-controlled device undergoes during a worker's fall must in no way lead to its failure.

Yes. In fact, UNI 11560:2022 requires that the interval between two periodic inspections (whether visual or instrumental) be no greater than 2 years for checks relating to the anchoring system and 4 years for checks relating to the supporting structure and anchors.

Yes. According to UNI 11560:2022, point 9.2.1, the system inspection after assembly must be performed by the installer and conducted in accordance with the instructions of the device manufacturer, the anchoring system designer, and the structural engineer. For anchors with the insertion of mechanical or chemical elements, the possibility of carrying out load tests that produce a tensile force of at least 5 kN for each anchor must be evaluated to verify the correct connection between the anchor and the supporting structure.

Yes. Since the purpose of an anchoring system is to connect the lifeline to a personal protective equipment (PPE) system to prevent falls from a height, a risk assessment must be performed prior to its design. This assessment involves analyzing the prevailing, concurrent, or subsequent risks and/or those associated with the work/activities to be performed on the roof.

It must necessarily be taken into consideration in order to design a system that protects the worker from such risks.

Pursuant to Article 59 of Legislative Decree No. 81/2008, liability lies with the worker if he or she fails to comply with safety obligations, observe personal protection provisions, use work equipment correctly, or participate in training programs.

In the event that the malfunction of one or more parts of an anchoring system is instead attributable to manufacturing or installation defects, the responsibility falls on the manufacturer and/or the installer.

UNI 11560:2022 indicates that the documentation to be provided to the client must contain:

  • Anchoring system configuration design (Technical Information for System Use), carried out by the anchoring system designer on the basis of the risk assessment.
  • Structural designer's verification project relating to the type of anchor to the supporting structure based on the type of material of the structure (Calculation Report).

According to Appendix A2 of UNI EN 795:2012 – Guide for documentation to be provided after installation, the necessary documentation that must be provided to the customer must include:

  • Schematic installation plan showing the address and location of the installation, the name and address of the installation company, the name of the person responsible for the installation, product identification (name of the anchor device manufacturer, type, model/article), fixing device (manufacturer, product, permissible tensile and transverse forces), schematic installation plan and relevant information for the user/client, such as the arrangement of the anchor points.

This plan should be posted at the entry point to the building so that it is visible or available to everyone.

  • Declaration of correct installation provided by the responsible installer, which must contain the following information regarding the anchor device: declaration of conformity of the installation with the installation instructions provided by the manufacturer in the use and maintenance manual, declaration of execution according to the installation plan, referred to above, declaration of fixing to the specified substrate and in the specified manner (number of bolts, correct materials, correct position, correct location), declaration that the work was commissioned in accordance with the manufacturer's information, photographic information/documentation.
  • Declaration of conformity of materials and instruction manuals for assembly, use and maintenance, issued by the manufacturer of the anchoring system.

Anchor points allow movement only in a circular area with a radius equal to the length of the lanyard, while lifelines allow linear movement along their entire length.

A rigid or track lifeline is an anchorage device that employs a rigid anchor line that deviates from the horizontal by no more than 15° (when measured between the end and intermediate anchors at any point along its length).

Main features:

  • System suitable for rope access work
  • System suitable for use in the presence of photovoltaic systems and for structures with low structural resistance
  • Low visual impact, good mobility and safety
  • Adaptability to the shape of the roof

Ask for more information